CMP1THR=LOW, CMP0CNT1EN=DISABLED, FCMP0EN=DISABLED, CMPHHYS=0_MV, FCMP1EN=DISABLED, CMPMD=5_US, CMPLHYS=0_MV, PEMD=LOW, CMP0THR=LOW
LC Configuration
PEMD | LC Pulse Extension Mode. 0 (LOW): Stretch the LC comparator output low pulses by approximately 20 ns. 1 (HIGH): Stretch the LC comparator output high pulses by approximately 20 ns. 2 (NONE): No pulse extension. |
CMP0FTH | LC Comparator 0 Fine Threshold. |
CMP0CTH | LC Comparator 0 Coarse Threshold. |
CMP0THR | LC Comparator 0 Threshold Range. 0 (LOW): Set the comparator 0 threshold to the low range (0 V to VIO/8 in 48 steps). 1 (FULL): Set the comparator 0 threshold to a full range (0 V to VIO in 64 steps). |
CMP1FTH | LC Comparator 1 Fine Threshold. |
CMP1CTH | LC Comparator 1 Coarse Threshold. |
CMP1THR | LC Comparator 1 Threshold Range. 0 (LOW): Set the comparator 1 threshold to the low range (0 V to VIO/8 in 48 steps). 1 (FULL): Set the comparator 1 threshold to a full range (0 V to VIO in 64 steps). |
CMPLHYS | LC Comparator Low-side Hysteresis. 0 (0_MV): Set both LC comparators to use 0 mV low-side hysteresis. 1 (5_MV): Set both LC comparators to use 5 mV low-side hysteresis. 2 (10_MV): Set both LC comparators to use 10 mV low-side hysteresis. 3 (20_MV): Set both LC comparators to use 20 mV low-side hysteresis. |
CMPHHYS | LC Comparator High-side Hysteresis. 0 (0_MV): Set both LC comparators to use 0 mV high-side hysteresis. 1 (5_MV): Set both LC comparators to use 5 mV high-side hysteresis. 2 (10_MV): Set both LC comparators to use 10 mV high-side hysteresis. 3 (20_MV): Set both LC comparators to use 20 mV high-side hysteresis. |
CMPMD | LC Comparator Mode. 0 (5_US): Mode 0 (slowest response time, lowest power consumption). 1 (1_US): Mode 1. 2 (400_NS): Mode 2. 3 (200_NS): Mode 3 (fastest response time, highest power consumption). |
CMP0CNT1EN | LC Comparator 0 to Count 1 Enable. 0 (DISABLED): Use LC comparator 0 as an input to counter 0 and LC comparator 1 as an input to counter 1. 1 (ENABLED): Use LC comparator 0 as an input to both counter 0 and counter 1. |
FCMP0EN | Force LC Comparator 0 On Enable. 0 (DISABLED): Hardware automatically turns LC comparator 0 on and off. 1 (ENABLED): Force LC comparator 0 always on. |
FCMP1EN | Force LC Comparator 1 On Enable. 0 (DISABLED): Hardware automatically turns LC comparator 1 on and off. 1 (ENABLED): Force LC comparator 1 always on. |